扬州市红旗电缆制造有限公司
Yangzhou Hongqi cables manufacturing Co., LTD
Technical description of Marine cable
A. The rated voltage Uo/U is 150/250V
B. Usage characteristics: 1. The working environment temperature range of the cable load is -15℃+70℃, and the maximum working temperature of the conductor of the cable is 90℃;
2. The minimum bending radius of the cable when laying:
Cable structure characteristics
|
Cable outer diameter D
|
Minimum bend radius
|
Metal braided armor type
|
Any value
|
6D
|
Non-armored type
|
D<=25
|
4D
|
D > 25
|
6D
|
C. Cable structure and characteristics (parameters see the following table) :
1.1 Model: CHJPFP96/NSC
1.2 Voltage class: 150/250V
1.3 Execution standard:
1.3.1 Structure: IEC60092-350, IEC60092-376
1.3.2 Conductor: IEC60228, Class 2
1.3.3 Insulation: IEC60092-360
1.3.4 Sheath: IEC60092-360
1.3.5 Flame retardant performance: IEC60332
1.3.6 Fire resistance: IEC60331
1.3.7 Smoke density: IEC61034-2
1.3.8 Halogen content: IEC60754-1
1.3.9 Maximum continuous operating temperature of conductor: 90℃
1.4 Structure Description
1.4.1 Conductor: tinned copper wire
1.4.2 Insulation: mica tape + crosslinked polyethylene
1.4.3 Individual + overalll shielding: aluminum-plastic composite tape (1*2*2.5, 1*3*2.5 wrap a layer of shielding)
1.4.4 Inner sheath: low smoke halogen-free inner sheath
1.4.5 Armor: galvanized steel wire braid
1.4.6 Outer sheath: low smoke halogen-free polyolefin sheath