扬州市红旗电缆制造有限公司
Yangzhou Hongqi cables manufacturing Co., LTD
Technical parameters of Marine variable frequency cable
A. Rated voltage Uo/U is 1.8/3kV.
B. Usage characteristics: The minimum bending radius of the cable when laying:
Cable structure characteristics
|
Cable outer diameter D
|
Minimum bend radius
|
Metal braided shield armor type
|
Any value
|
8D
|
C. Cable structure and characteristics (parameters see the table below) :
Model: CJ86/SC-VFD 1.8/3kV flame retardant Marine frequency conversion cable
1. Implementation standard:
1.1 Structure: IEC60092-350, IEC60092-353
1.2 Conductor: IEC60228, Class 5
1.3 Insulation: IEC60092-360
1.4 Sheath: IEC60092-360
Flame retardant performance: IEC60332-3-22
1.6 Smoke density: IEC61034-2
1.7 Halogen content: IEC60754-1
1.8 The maximum operating temperature of the conductor is 90 ° C
2、 Structure Description
2.1 Conductor: tinned copper wire
2.2 Insulation: XLPE- crosslinked polyethylene
2.3 Shielding layer: copper-plastic composite tape + discharge line
2.4 Armouring: tinned copper wire braid
2.6 Outer sheath: low smoke halogen-free polyolefin sheath