A. Rated voltage Uo/U is 0.6/1kV.
B. Usage characteristics: 1. The ambient temperature of the cable load ranges from -15℃ to +70℃, and the maximum operating temperature of the conductor is +90℃;
C. Cable structure and characteristics (parameters see the following table) :
1. Low smoke halogen-free Marine power cable:
1.1 TYPE: CEPJ85/SC
1.2 Voltage level: 0.6/1kV
1.3 Implementation Standards:
1.3.1 Structure: IEC60092-350, IEC60092-353
1.3.2 Conductor: IEC60228, Class 2
1.3.3 Insulation: IEC60092-360
1.3.4 Sheath: IEC60092-360
1.3.5 Flame retardant performance: IEC60332
1.3.6 Smoke density: IEC61034-2
1.3.7 Halogen content: IEC60754-1
1.3.8 Maximum continuous operating temperature of conductor: 90℃
1.4 Structure Description:
1.4.1 Conductor: Tinned copper wires
1.4.2 Insulation: ethylene and propylene insulation
1.4.3 Inner sheath: low smoke halogen-free polyolefin inner sheath
1.4.4 Armouring: tinned copper wire armouring